Sonel MPI-540 + EVSE-01 Multi-Function Meter of Electrical System Parameters & Adapter
Brand: Sonel
View Details
Quantity: In Stock
Selected variant:
Selected variant:
Index: WMGBMPI540EVSE01
Description
SONEL MPI-540 + SONEL EVSE-01 SET
1. Multi-function meter of electrical system parameters Sonel MPI-540
The Sonel MPI-540 multifunctional meter is intended for testing home and industrial electrical installations. The instrument can be used to carry out measurements, the results of which determine the safety status of the installation. In addition, the user is able to record the parameters of the electrical networks located at these sites. This makes it possible to control the quality of electricity, and to measure electric shock protection parameters, using a single universal device.
Significant automation of measurements is made possible by the function of testing residual current circuit breakers in Auto mode, as well as measurement sequences pre-programmed by the manufacturer (so-called self-tests), which can also be extended with own sequences. Automatic measurement of insulation resistance of 3-, 4- and 5-core cables will be carried out with the Sonel AutoISO-1000C adapter.
2. Adapter for testing vehicle charging stations Sonel EVSE-01
Sonel EVSE-01 adapter allows to perform comprehensive measurements of electric vehicle charging stations - quickly and in accordance with applicable regulations. Simulating the charging cable (proximity pilot line - PP) and vehicle connection status (control pilot line - CP), it will bring the station into different operating states. This will enable measurements in the field of electric shock protection: ZS fault loop impedance, RISO insulation resistance and checking the parameters of RCD residual current devices.
To facilitate diagnostics, one of the Sonel EVSE-01 sockets is provided with pulse width modulation signal (PWM).
Application
The Sonel EVSE-01 adapter enables measurements of AC electric vehicle charging stations with type 2 connector. Tests for 1-phase and 3-phase stations are available - both with and without ventilation.
Technical Specification
MPI-540 | Specifications – electrical installation parameters
Measurement functions | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Fault loop impedance | ||||
Fault loop ZL-PE, ZL-N, ZL-L | 0.13 Ω…1999.9 Ω acc. to IEC 61557 | 0.00 Ω…1999 Ω | from 0.001 Ω | ±(5% m.v. + 30 digits) |
Fault loop ZL-PE in RCD mode | from 0.50 Ω…1999 Ω acc. to IEC 61557 | 0.00 Ω…1999 Ω | from 0.01 Ω | from ±(6% m.v. + 5 digits) |
Measurements of RCD parameters | ||||
RCD tripping test and measurement of tripping time tA measuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn | ||||
general and short-time delay RCD | 0 ms…300 ms | 0 ms…300 ms | 1 ms | from ±(2% m.v. + 2 digits) |
selective RCD | 0 ms…500 ms | 0 ms…500 ms | 1 ms | from ±(2% m.v. + 2 digits) |
Measurement of RCD tripping current IA measuring current 0 0.2 IΔn…2.0 IΔn | ||||
for sinusoidal residual current (AC type) | 3.3 mA…1000 mA | 3.3 mA…1000 mA | from 0.1 mA | ±5% IΔn |
for unidirectional residual current and unidirectional with the 6 mA DC bias (type A) | 3.5 mA…700 mA | 3.5 mA…700 mA | from 0.1 mA | ±10% IΔn |
for direct residual current (type B)) | 2.0 mA…1000 mA | 2.0 mA…1000 mA | from 0.1 mA | ±10% IΔn |
Earth resistance | ||||
3- and 4-pole method | from 0.50 Ω…1.99 kΩ acc. to IEC 61557-5 | 0.00 Ω…1,99 kΩ | from 0.01 Ω | from ±(2% m.v. + 3 digits) |
3-pole + clamp method | 0.00 Ω…1.99 kΩ | 0.00 Ω…1.99 kΩ | from 0.01 Ω | from ±(2% m.v. + 4 digits) |
2-clamp method | 0.00 Ω…99.9 kΩ | 0.00 Ω…99.9 kΩ | from 0.01 Ω | from ±(10% m.v. + 4 digits) |
Resistance-to-earth | 0.0 Ω m…99.9 kΩm | 0.0 Ωm…99.9 kΩm | from 0.1 Ωm | Depending on accuracy of RE measurement |
Insulation resistance | ||||
Measuring voltage 50 V | 50 kΩ…250 MΩ acc. to IEC 61557-2 | 0 kΩ…250 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 100 V | 100 kΩ…500 MΩ acc. to IEC 61557-2 | 0 kΩ…500 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 250 V | 250 kΩ…999 MΩ acc. to IEC 61557-2 | 0 kΩ…999 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 500 V | 500 kΩ…2.00 GΩ acc. to IEC 61557-2 | 0 kΩ…2.00 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 1000 V | 1000 kΩ…9.99 GΩ acc. to IEC 61557-2 | 0 kΩ…9.99 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.12 Ω…400 Ω acc. to IEC 61557-4 | 0.00 Ω…400 Ω | from 0.01 Ω | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | 0.0 Ω…1999 Ω | 0.0 Ω…1999 Ω | from 0.1 Ω | ±(3% m.v. + 3 digits) |
Light intensity | ||||
Measurement in luxes (lx) | 0 lx…399.9 klx | 0 lx…399.9 klx | from 0.001 lx | from ±(2% m.v. + 5 digits) |
Measurement in feet-candles (fc) | 0 fc…39.99 kfc | 0 fc…39.99 kfc | from 0.001 fc | from ±(2% m.v. + 5 digits) |
Phase sequence indication | in the same direction (correct), opposite direction (incorrect), UL-L voltage: 95 V…500 V (45 Hz…65 Hz) |
“m.v.” - measured value
MPI-540 | Specifications – 3-phase power quality recorder
The device is designed to work with mains:
- with nominal frequency 50/60 Hz
- with nominal voltage: 64/110 V, 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 254/440 V, 290/500 V
- DC networks
Supported systems:
- single-phase
- split-phase with common N
- three-phase – WYE with and without N conductor
- three-phase – Delta
Parameter | Measuring range | Max. resolution | Accuracy |
---|---|---|---|
Alternating voltage (TRMS) | 0.0…500 V | 0.01% Unom | ±0,5% Unom |
Alternating current (TRMS) | depending on clamp* | 0.01% Inom | ±2% m.v. if m.v. ≥ 10% Inom, ±2% Inom if m.v. < 10% Inom , (error does not account for clamp error) |
Frequency | 40.00…70.00 Hz | 0.01 Hz | ±0.05 Hz |
Active, reactive, apparent and distortion power | depending on configuration (transducers, clamps) | 4 significant digits | depending on configuration (transducers, clamps) |
Active, reactive and apparent energy | depending on configuration (transducers, clamps) | 4 significant digits | as power error |
cosφ and power factor (PF) | 0.00…1.00 | 0.01 | ±0.03 |
Harmonics | |||
Voltage | as for alternating voltage True RMS | as for alternating voltage True RMS | ±5% m.v. if m.v. ≥ 3% Unom, ±0,15% Unom if m.v. < 3% Unom |
Current | as for alternating current True RMS | as for alternating current True RMS | ±5% m.v. if m.v. ≥ 10% Unom, ±0,5% Unom if m.v. < 10% Unom |
THD | |||
Voltage | 0.0…100.0% (relative to RMS value) | 0.1% | ±5% |
Current | 0.0…100.0% (relative to RMS value) | 0.1% | ±5% |
Unbalance factor | 0.0…10.0% | 0.1% | ±0.15% (absolute error) |
*
- F-1A, F-2A, F-3A clamp: 0…3000 A AC (10 000 Ap-p)
- C-4A clamp: 0…1000 A AC (3600 Ap-p)
- C-5A clamp: 0…1000 A AC/DC (3600 Ap-p)
- C-6A clamp: 0..10 A AC (36 Ap-p)
- C-7A clamp: 0…100 A AC (360 Ap-p)
MPI-540 | AC currentmeasurment (True RMS) with clamp
C-4A | C-5A | C-6A | C-7A | F-1A | F-2A | F-3A | |
---|---|---|---|---|---|---|---|
Rated current | 1000 A AC | 1000 A AC 1400 A DC |
10 A AC | 100 A AC | 3000 A AC | 3000 A AC | 3000 A AC |
Frequency | 30 Hz…10 kHz | DC…5 kHz | 40 Hz…10 kHz | 40 Hz…1 kHz | 40 Hz…10 kHz | 40 Hz…10 kHz | 40 Hz…10 kHz |
Max. diameter of measured conductor | 52 mm | 39 mm | 20 mm | 24 mm | 380 mm | 250 mm | 140 mm |
Minimum accuracy | ≤0,5% | ≤1,5% | ≤1% | 0,5% | 1% | 1% | 1% |
Battery power | - | √ | - | - | - | - | - |
Lead length | 2.2 m | 2.2 m | 2.2 m | 3 m | 2.5 m | 2.5 m | 2.5 m |
Measurement category | IV 300 V | IV 300 V | IV 300 V | III 300 V | IV 600 V | IV 600 V | IV 600 V |
Ingress protection | IP40 | IP40 | IP40 | IP40 | IP67 | IP67 | IP67 |
EVSE-01 | Functional comparison
MPI-540-PV MPI-540 MPI-536 MPI-535 | MPI-530-IT MPI-530 MPI-525 MPI-520 | MPI-507 MPI-506 | MPI-502F | |
---|---|---|---|---|
auto measurements | √ | - | - | - |
automatic threephase measurement via multiplug | √ | - | - | - |
visual inspection | √ | - | - | - |
fault loop ZL-PE, ZL-N parameters measurement | √ | √ | √ | √ |
6 mA RCD test | √ | - | - | - |
RCD test | AC, A, F, B, B+, EV | AC, A, F, B, B+ | AC, A | AC, A |
insulation resistance RISO measurement | √ | √ | √ | - |
measurements report | √ | √ | √ | √ |
Specifications